Leakage estimate
Use an isolated, no-demand pressure decay test or measured flow.
New projects stay in memory until you choose Save or Export. Local saving is not a cloud account. Contacts are excluded from saved project files.
Calculations run on this device. A result is a preliminary estimate, not engineering approval. No documented model operating points have been imported yet.
Qleak=V ΔP/(Pref t) × Tref/Tsystem. Decay mode needs isolated supply, no production/residual demand and dry air. The measured temperature change must be within ±0.2 °C; pressure is limited to 16 bar absolute and temperature to −20…120 °C. Measured mode needs its source and a confirmed flow basis. This is a mean over the test pressure band, not a universal leak rate or promised energy saving.
Required data & method sources
- Decay: effective volume, start/end absolute pressure, duration and reference/system temperatures
- Decay: measured temperature stability, documented isolation, no normal demand and dry air
- Measured mode: actual leak flow, measurement source and common reference-basis confirmation
Method references only; not manufacturer performance data or engineering approval.
- Equation of State — Equation p V = n R T
- Improving Compressed Air System Performance, Third Edition — Printed pp. 20–23, 28–29, 43–44, 58–59